Fabrication of a Cell Fixation Device for Robotic Cell Microinjection
Yu Xie, Yunlei Zhou, Wenming Xi, Songyue Chen
- 发表年份
- 2016
- 引用次数
- 3
- 访问权限
- 开放获取
摘要
Automation of cell microinjection greatly reduces operational difficulty, but cell fixation remains a challenge. Here, we describe an innovative device that solves the fixation problem without single-cell operation. The microarray cylinder is designed with a polydimethylsiloxane (PDMS) material surface to control the contact force between cells and the material. Data show that when the injection velocity exceeds 1.5 mm/s, microinjection success rate is over 80%. The maximum value of the adhesion force between the PDMS plate and the cell is 0.0138 N, and the need can be met in practical use of the robotic microinjection.