Inverse Transmission Model and Compensation Control of a Single-Tendon–Sheath Actuator
Lin Chen, Xingsong Wang, Wei Xu
- Year
- 2013
- Citations
- 88
Abstract
Tendon-sheath actuation mechanism is popular in many applications such as surgical robots, robotic hands, and exoskeleton devices due to its simplicity, dexterity, and remote transmission. There exist, however, undesirable nonlinear dynamic properties like backlash, hysteresis, and friction in tendon-sheath transmission. Controlling the distal-end position and force accurately is a very challenging task, since the needed sensors can hardly be placed at the distal end of the system. This paper develops a displacement transmission model of a single-tendon-sheath transmission system based on the force transmission model and proposes a new approach to control the distal-end force and position by inverse transmission without any feedback from the output side. The inverse model is calibrated by offline measurements using the sensors mounted at the proximal end. An experimental setup of single-tendon-sheath actuation is presented, and the improved control performance, with respect to distal-end position and force tracking, is validated by experiments.
Keywords
Related papers
Applied Nonlinear Control
Jean-Jacques Slotine, Weiping Li
1991
Real-Time Obstacle Avoidance for Manipulators and Mobile Robots
Oussama Khatib
1986
A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses
R. Tsai
1987
Introduction to Robotics mechanics and Control
John Craig
1986