首页 /研究 /Reliable Activation of an EPM-Based Clinging Device for Aerial Inspection Robots
OTHER

Reliable Activation of an EPM-Based Clinging Device for Aerial Inspection Robots

Arata MASUDA, Akihiro Tanaka, Yoshiyuki Higashi, Nanako MIURA

发表年份
2019
引用次数
12

摘要

This study aims to develop a clinging device for structural inspection robots, which are expected to be used to reduce the cost of inspection of aging civil infrastructure and industrial structures. In a previous study, an electro-permanent magnet (EPM)-based clinging device that could electrically turn on and off the magnetic adhesive force against steel structures was proposed. In this study, a more versatile design of the clinging device was firstly presented, and a considerable difficulty regarding the activation process of the EPM which might impair the reliability of the clinging device was stated based on mathematical modeling and experiments. The concept of a two-step activation process was then presented to overcome the stated difficulty, and its implementation using a limit switch-based contact sensor was successfully demonstrated through collision tests. Furthermore, sensorless realization of contact detection by measuring the induced voltage across the coil of the EPM was proposed, and its feasibility was validated.

关键词

RobotReliability (semiconductor)Process (computing)Computer scienceVoltageElectromagnetic coilRealization (probability)ActuatorMagnetAutomotive engineering

相关论文

查看 OTHER 分类全部论文