Individualised positive end-expiratory pressure titrated intra-operatively by electrical impedance tomography optimises pulmonary mechanics and reduces postoperative atelectasis
Xiaojing Ma, Yunke Fu, Xiangmei Piao, Roberta Ribeiro De Santis Santiago, Libin Ma, Ying Guo, Qiang Fu, Weidong Mi, Lorenzo Berra, Changsheng Zhang
- 发表年份
- 2023
- 引用次数
- 21
摘要
BACKGROUND: A protective intra-operative lung ventilation strategy has been widely recommended for laparoscopic surgery. However, there is no consensus regarding the optimal level of positive end-expiratory pressure (PEEP) and its effects during pneumoperitoneum. Electrical impedance tomography (EIT) has recently been introduced as a bedside tool to monitor lung ventilation in real-time. OBJECTIVE: We hypothesised that individually titrated EIT-PEEP adjusted to the surgical intervention would improve respiratory mechanics during and after surgery. DESIGN: Randomised controlled trial. SETTING: First Medical Centre of Chinese PLA General Hospital, Beijing. PATIENTS: Seventy-five patients undergoing robotic-assisted laparoscopic hepatobiliary and pancreatic surgery under general anaesthesia. INTERVENTIONS: Patients were randomly assigned 2 : 1 to individualised EIT-titrated PEEP (PEEPEIT; n = 50) or traditional PEEP 5 cmH2O (PEEP5 cmH2O; n = 25). The PEEPEIT group received individually titrated EIT-PEEP during pneumoperitoneum. The PEEP5 cmH2O group received PEEP of 5 cmH2O during pneumoperitoneum. MAIN OUTCOME MEASURES: The primary outcome was respiratory system compliance during laparoscopic surgery. Secondary outcomes were individualised PEEP levels, oxygenation, respiratory and haemodynamic status, and occurrence of postoperative pulmonary complications (PPCs) within 7 days. RESULTS: Compared with PEEP5 cmH2O, patients who received PEEPEIT had higher respiratory system compliance (mean values during surgery of 44.3 ± 11.3 vs. 31.9 ± 6.6, ml cmH2O-1; P < 0.001), lower driving pressure (11.5 ± 2.1 vs. 14.0 ± 2.4 cmH2O; P < 0.001), better oxygenation (mean PaO2/FiO2 427.5 ± 28.6 vs. 366.8 ± 36.4; P = 0.003), and less postoperative atelectasis (19.4 ± 1.6 vs. 46.3 ± 14.8 g of lung tissue mass; P = 0.003). Haemodynamic values did not differ significantly between the groups. No adverse effects were observed during surgery. CONCLUSION: Individualised PEEP by EIT may improve intra-operative pulmonary mechanics and oxygenation without impairing haemodynamic stability, and decrease postoperative atelectasis. TRIAL REGISTRATION: Chinese Clinical Trial Registry (www.chictr.org.cn) identifier: ChiCTR2100045166.
关键词
相关论文
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz 等 11 位作者
2012
Campbell-Walsh urology
Alan J. Wein editor-in-chief
2012
Stroke rehabilitation
Peter Langhorne, Julie Bernhardt, Gert Kwakkel
2011