Home /Research /Hand exoskeleton for rehabilitation therapies with integrated optical force sensor
OTHER

Hand exoskeleton for rehabilitation therapies with integrated optical force sensor

Jorge A. Díez, Andrea Blanco, José Catalán, Francisco J. Badesa, Luís D. Lledó, Nicolás García-Aracil

Year
2018
Citations
62
Access
Open access

Abstract

This article presents the design of a hand exoskeleton that features its modularity and the possibility of integrating a force sensor in its frame. The modularity is achieved by dividing the exoskeleton in separate units, each one driving a finger or pair of them. These units or “finger modules” have a single degree of freedom and may be easily attached or removed from the robot frame and human fingers by snap-in fixations. As for the force sensing capability, the device relies on a novel force sensor that uses optical elements to amplify and measure small elastic deformations in the robot structure. This sensor can be fully integrated as a structural element of the finger module. The proposed technology has been validated in two experimental sessions. A first study was performed in a clinical environment in order to check whether the hand exoskeleton (without the integrated force sensor) can successfully move an impaired hand in a “Mirror Therapy” environment. A second study was carried with healthy subjects to check the technical feasibility of using the integrated force sensor as a human–machine interface.

Keywords

ExoskeletonModularity (biology)Interface (matter)Computer scienceRobotFrame (networking)SimulationEngineeringArtificial intelligenceHuman–robot interaction

Related papers

Browse all OTHER papers