首页 /研究 /EXPERIMENTAL CALIBRATION OF THE CONSTRAINING LINKAGE OF A 4 DEGREES OF FREEDOM PARALLEL MANIPULATOR
MANIPULATION

EXPERIMENTAL CALIBRATION OF THE CONSTRAINING LINKAGE OF A 4 DEGREES OF FREEDOM PARALLEL MANIPULATOR

Leila Notash, Andrew Horne, Victoria Lee

发表年份
2007
引用次数
2

摘要

In this article, an experimental calibration of the constraining linkage of a wire-actuated parallel robot is discussed. The experimental test bed includes a prototyped 4 degrees of freedom wire-actuated parallel manipulator and an optical tracking system. The parallel manipulator employs hybrid actuation of joints and wires and includes a rigid branch to constrain the motion of its mobile platform in roll and yaw rotations. The kinematic calibration of the rigid branch is performed. A point-to-point path is designed for the manipulator and an optical tracking system is used as an external measuring device to track a tool attached to the mobile platform and to register the manipulator poses. The deviation between the actual (measured) pose of the mobile platform and the calculated pose (via direct kinematics using the joint encoders), which could be due to errors in the kinematic parameters, actuators and sensors, is used as the error function.

关键词

Parallel manipulatorKinematicsLinkage (software)Mobile manipulatorCalibrationActuatorControl theory (sociology)EncoderComputer scienceRotary encoder