首页 /研究 /Robotic Assisted Ultrasound‐Guided Endovascular Stent Implantation in a Vascular Model
OTHER

Robotic Assisted Ultrasound‐Guided Endovascular Stent Implantation in a Vascular Model

Alexandra Scheibert, Mark Preuss, Jonas Osburg, Floris Ernst, Markus Kleemann, Marco Horn

发表年份
2024
引用次数
2
访问权限
开放获取

摘要

BACKGROUND: Endovascular procedures are the preferred method for treating peripheral arterial disease. However, limited imaging options during these procedures, such as X-rays and contrast media, expose patients and healthcare professionals to potentially harmful radiation. This study introduces a robotic ultrasound system (RUSS) for navigating endovascular procedures in order to reduce radiation and provide additional information. METHODS: The RUSS comprises a seven-degree-of-freedom robotic arm that navigates an ultrasound transducer across a specific region of interest. The system is controlled by a self-programed software designed to navigate the robotic arm in a methodical and reproducible manner using a foot switch. RESULTS: An endovascular surgeon investigated the guidance and visibility of various guidewires and successfully implanted three stents in a vascular leg phantom using the RUSS without further radiation exposure. CONCLUSIONS: The innovative set-up has several potential applications, including radiation-free endovascular procedures as well as health screening and diagnostic support in vascular medicine.

关键词

Imaging phantomMedicineUltrasoundEndovascular surgeryRadiologyMedical physicsStentArterial diseaseComputer scienceSurgery

相关论文

查看 OTHER 分类全部论文