首页 /研究 /Intraoperative Kirschner Wire Migration during Robotic Minimally Invasive Spine Surgery
SURGICAL

Intraoperative Kirschner Wire Migration during Robotic Minimally Invasive Spine Surgery

Ashley Peterson, Lynn K. Ngai, Mark A. Burbridge

发表年份
2019
引用次数
3
访问权限
开放获取

摘要

We present the case of a 58-year-old woman who underwent a minimally invasive robotic-assisted L4-S1 instrumentation and fusion which was complicated by a Kirschner wire (K-wire) fracture and migration into the abdominal cavity necessitating emergent exploratory laparotomy. Retrieval of the K-wire proceeded without incident, and the patient had an otherwise uneventful surgery and recovery. This is the first such case description reported in the literature. As minimally invasive robotic-assisted spine procedures become more common, it is essential for the anesthesiologist to be familiar with potential complications to manage such patients in the perioperative period optimally.

关键词

MedicinePerioperativeSurgeryKirschner wireExploratory laparotomyInvasive surgeryLaparotomyGeneral surgeryInternal fixation