Feasibility and Accuracy of a Novel Hands-Free Robotic System for Percutaneous Needle Insertion and Steering.

Agnieszka Witkowska, Shiran Levy, Ido Roth, Moran Shochat, Danielle Bradbury, Jacob Sosna, Isaac Leichter, S. Nahum Goldberg, Sebastian Flacke

发表年份
2022
引用次数
11

摘要

PURPOSE: To assess the performance and accuracy of CT-guided needle insertion for clinical biopsies using a novel, hands-free robotic system that balances accuracy with the duration of the procedure and radiation dose. MATERIALS AND METHODS: A prospective, multi-center study was conducted on 60 clinically indicated biopsies of abdominal lesions at two centers (Center 1, n=26; Center 2, n=34). CT datasets were obtained for planning and controlled placement of 17g and 18g needles using a patient-mounted, CT-guided robotic system with 5 degrees of freedom. Planning included target selection, skin entry point, and predetermined checkpoints where additional imaging was performed to permit stepwise correction of the needle trajectory. Success rate, needle tip-to-target distance, number of checkpoints used, number of trajectory corrections, procedure duration, and effective radiation dose were recorded and compared between centers. RESULTS: In 55 of 60 procedures (91.7%), the robot positioned the trocar needle successfully on target. In the remaining 5 patients, the procedure was manually performed by the operator due to technical failure (n=3) or patient-related factors (n=2). The average lesion size was 2.8 ± 1.7cm with a lesion depth from the skin of 8.7 ± 2.6cm, and there was no difference between centers. The overall accuracy (needle tip-to-target distance) was 1.71 ± 1.49 (range 0.05-7.20mm), with an accuracy of 2.06 ± 1.45 mm at Center 1 and 1.45 ± 1.52 mm at Center 2 (p=0.1358). Center 1 used significantly more checkpoints (4.96 ± 1.08) and performed target adjustments in 20 of 24 (83%) cases compared to Center 2 (2.77 ± 0.6 checkpoints and target adjustments in 13 of 31 cases, 42%) (p=0.0024). Accordingly, the steering duration from skin entry to the target varied between Centers 1 and 2; 13.1min ± 4.25min vs. 5.7min ± 2.7min, respectively (p <0.001). The average DLP for the entire procedure was 1147 ± 820 mGycm, with a slightly lower average at Center 2 (1031 ± 724 mGycm) compared to Center 1 (1297 ± 925 mGycm) (p=0.236). CONCLUSION: Accurate needle-targeting within an error of 2mm can be achieved in patients using a CT-guided robotic system. The variation in the number of checkpoints did not affect system accuracy but was related to shorter steering times and may contribute to a lower radiation dose. Accurate needle insertion using a hands-free CT-guided robotic system may facilitate difficult needle placement and enhance the performance of less-experienced interventionalists.

关键词

MedicinePercutaneousTarget lesionNuclear medicineRadiation exposureRadiologySurgery

相关论文

查看 OTHER 分类全部论文