Home /Research /High-performance 2-D force display system using MR actuators
OTHER

High-performance 2-D force display system using MR actuators

Yuki Yamaguchi, J. Furusho, Shinya Kimura, K. Koyanagi

Year
2005
Citations
11

Abstract

A force display system is a kind of human-coexistent robot systems, which share the space with people while they are working, and which directly touch and display force-senses to their users. For such a robot system, it is important to estimate safety quantitatively and to ensure mechanical safety. In this paper, it is described that using MR (magneto-rheological) actuators, which is one clutch type actuators, can ensure safety. Moreover, the characteristics of MR actuators that are low inertia, high torque/inertia ratio and high responsibility contribute to improve the performance of force display systems. In this study, we developed an MR actuator with low inertia (2.6/spl times/10/sup -5/[kg/spl middot/ m/sup 2/]), high torque/inertia ratio (3.8/spl times/10/sup 5/[1/s/sup 2/]) and high responsibility. Torque/inertia ratio of this MR actuator is highest among MR actuators developed so far and much higher than those of conventional servo actuators. Then, a high-performance 2-D force display system using the MR actuator was developed. Maximum force displayed is 190 [N] and rigidity of the system is 5.9 [N/mm]. Moreover, backdrivability, dynamic range and collision sense are improved by using MR actuators in comparison with a system using ER actuators.

Keywords

ActuatorTorqueClutchInertiaRotary actuatorRigidity (electromagnetism)RobotComputer scienceServomotorControl theory (sociology)

Related papers

Browse all OTHER papers