Abstract
This article presents preliminary stochastic estimates of the multi-variable human ankle mechanical impedance. We employed Anklebot, a rehabilitation robot for the ankle, to provide torque perturbations. Time histories of the torques in Dorsi-Plantar flexion (DP) and Inversion-Eversion (IE) directions and the associated angles of the ankle were recorded. Linear time-invariant transfer functions between the measured torques and angles were estimated for the Anklebot and when the Anklebot was worn by a human subject. The difference between these impedance functions provided an estimate of the mechanical impedance of the ankle. High coherence was observed over a frequency range up to 30 Hz, indicating that this procedure yielded an accurate measure of ankle mechanical impedance in DP and IE directions.