Home /Research /Pneumatic Control of Robots for Rehabilitation
OTHER

Pneumatic Control of Robots for Rehabilitation

Eric T. Wolbrecht, David J. Reinkensmeyer, J.E. Bobrow

Year
2009
Citations
46

Abstract

Pneumatic actuators are attractive for robotic rehabilitation applications because they are lightweight, powerful, and compliant, but their control has historically been difficult, limiting their use. In this paper we present the pneumatic control system developed for Pneu-WREX: a pneumatically actuated, upper extremity orthosis for rehabilitation after stroke. The developed pneumatic control system combines several novel components to make the entire system stable, reliable, and backdrivable. These components, which are described in this paper, include: (1) a unique two-valve force control subsystem that keeps chamber pressure low (to reduce friction and energy consumption) and adaptively compensates for leakage; (2) a new servovalve characterization approach that uses experimentally measured data in a combined non-linear and least-squares regression to obtain a linear relationship between mass flow and valve voltage; and (3) a new approach to state estimation using accelerometers and a Kalman filter to obtain clean signals for use in a non-linear adaptive feedback control law. Experimental testing of the device demonstrates the efficacy of the developed pneumatic control system.

Keywords

Control theory (sociology)Pneumatic flow controlControl engineeringKalman filterControl systemControl valvesEngineeringRobotPneumatic actuatorActuator

Related papers