首页 /研究 /Implantation technique, safety and complications of robot-assisted stereoelectroencephalography exploration of the limbic thalamus in human focal epilepsy
SURGICAL

Implantation technique, safety and complications of robot-assisted stereoelectroencephalography exploration of the limbic thalamus in human focal epilepsy

Ganne Chaitanya, Andrew Romeo, Adeel Ilyas, Auriana Irannejad, Emília Tóth, Galal Elsayed, J. Nicole Bentley, Kristen Riley, Sandipan Pati

发表年份
2020
引用次数
3
访问权限
开放获取

摘要

Abstract Introduction Despite numerous imaging studies highlighting the importance of thalamus in surgical prognosis, human electrophysiological studies involving the limbic thalamic nuclei are limited. The objective of this study was to evaluate the safety and accuracy of robot-assisted stereotactic electrode placement in the limbic thalamic nuclei in patients with suspected temporal lobe epilepsy (TLE). Methods After obtaining informed consent, 24 adults with drug-resistant suspected TLE undergoing Stereo-EEG evaluation were enrolled in this prospective study. The trajectory of one electrode planned for clinical sampling the operculo-insular cortex was modified to extend to the thalamus, thereby preventing the need for additional electrode placement for research. The anterior thalamus (ANT) (N=13) and the medial group of thalamic nuclei (MED) (N=11), including mediodorsal (MD) and centromedian (CeM) were targeted. The post-implantation CT was co-registered to the pre-operative MRI, and Morel’s thalamic atlas was used to confirm the accuracy of implantation. Results Ten out of 13 (77%) in the ANT group and 10 out of 11 patients (90%) in the medial group had electrodes accurately placed in the thalamic nuclei. None of the patients had a thalamic hemorrhage. However, trace asymptomatic hemorrhages at the cortical level entry site were noted in 20.8% of patients and they did not require additional surgical intervention. SEEG data from all the patients were interpretable and analyzable. The trajectories for the ANT implant differed slightly from the medial group at the entry point i.e., precentral gyrus in the former and postcentral gyrus in the latter. Conclusions Using judiciously planned robot-assisted SEEG, we demonstrate the safety of electrophysiological sampling from various thalamic nuclei for research recordings, presenting a technique that avoids implanting additional depth electrodes, or comprising clinical care. With these results, we propose that if patients are fully informed of the risks involved, there are potential benefits of gaining mechanistic insights to seizure genesis, which may help to develop neuromodulation therapies.

关键词

StereoelectroencephalographyThalamusPostcentral gyrusMedicineElectrocorticographyEpilepsyTemporal lobeEpilepsy surgeryGyrusNeuroscience

相关论文

查看 SURGICAL 分类全部论文