Thermal performance of non-metallic two-phase cold plates for humanoid robot cooling
Kyudae Hwang, Suk Won Lee, Sarng Woo Karng, Seoyoung C. Kim
- 发表年份
- 2008
- 引用次数
- 8
摘要
For the reliable and continuous operation of humanoid robot, various types of multiple heat sources such as CPUs, motors, drivers should be cooled down by using compact and light-weight cooling devices. In this study, thermal performances of one metallic cold plate and two different types of non-metallic cold plates with a dielectric coolant (FC-72) as a working fluid are investigated in two-phase circulation without any external driving force. All types of cold plates have the same dimension of 32times26 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> base area with 7 mm in height. A metallic cold plate was fully made of copper. Two non-metallic polycarbonate (PC) cold plates, which are designed to reduce the overall weight of robot cooling system, are composed of a PC cover with two copper different bases. All cold plates are mounted on a 20times20 mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> copper heating block with two cartridge heaters of 30 W/cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> . It is found that both of PC cold plates show higher thermal performance compared to the copper cold plate in terms of thermal resistance based on a unit mass.
关键词
相关论文
Statistical Learning Theory
Yuhai Wu, Vladimir Vapnik
1999
Fractional Differential Equations
Igor Podlubný
2025
Applied Nonlinear Control
Jean-Jacques Slotine, Weiping Li
1991
Genetic Programming: On the Programming of Computers by Means of Natural Selection
John R. Koza
1992