首页 /研究 /Data-Driven Modelling and Control for Robot Needle Insertion in Deep Anterior Lamellar Keratoplasty
SURGICAL

Data-Driven Modelling and Control for Robot Needle Insertion in Deep Anterior Lamellar Keratoplasty

William R. Edwards, Gao Tang, Yuan Tian, Mark Draelos, Joseph A. Izatt, Anthony N. Kuo, Kris Hauser

发表年份
2022
引用次数
18
访问权限
开放获取

摘要

Deep anterior lamellar keratoplasty (DALK) is a technique for cornea transplantation which is associated with reduced patient morbidity. DALK has been explored as a potential application of robot microsurgery because the small scales, fine control requirements, and difficulty of visualization make it very challenging for human surgeons to perform. We address the problem of modelling the small scale interactions between the surgical tool and the cornea tissue to improve the accuracy of needle insertion, since accurate placement within 5% of target depth has been associated with more reliable clinical outcomes. We develop a data-driven autoregressive dynamic model of the tool-tissue interaction and a model predictive controller to guide robot needle insertion. In an <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">ex vivo</i> model, our controller significantly improves the accuracy of needle positioning by more than 40% compared to prior methods.

关键词

CorneaRobotArtificial intelligenceComputer scienceBiomedical engineeringComputer visionSurgeryMedicineOphthalmology

相关论文

查看 SURGICAL 分类全部论文