Gait Training Using the Honda Walking Assistive Device® in a Patient Who Underwent Total Hip Arthroplasty: A Single-Subject Study
Kazunori Koseki, Hirotaka Mutsuzaki, Kenichi Yoshikawa, Yusuke Endo, Takayuki Maezawa, Hanako Takano, Arito Yozu, Yutaka Kohno
- 发表年份
- 2019
- 引用次数
- 19
- 访问权限
- 开放获取
摘要
BACKGROUND AND OBJECTIVES: The Honda Walking Assistive device® (HWA) is a light and easywearable robot device for gait training, which assists patients' hip flexion and extension movementsto guide hip joint movements during gait. However, the safety and feasibility of robot-assisted gaittraining after total hip arthroplasty (THA) remains unclear. Thus, we aimed to evaluate the safetyand feasibility of this gait training intervention using HWA in a patient who underwent THA. MATERIALS AND METHODS: The patient was a 76-year-old woman with right hip osteoarthritis. Gaittraining using HWA was implemented for 20 sessions in total, five times per week from 1 week to5 weeks after THA. Self-selected walking speed (SWS), step length (SL), cadence, timed up and go(TUG), range of motion (ROM) of hip extension, and hip abduction and extension torque weremeasured preoperatively, and at 1 (pre-HWA), 2, 3, 4, 5 (post-HWA), and 10 weeks (follow-up) afterTHA. The gait patterns at SWS without HWA were measured by using three-dimensional (3D) gaitanalysis and an integrated electromyogram (iEMG). RESULTS: The patient completed 20 gait trainingsessions with no adverse event. Hip abduction torque at the operative side, hip extension torque,SWS, SL, and cadence were higher at post-HWA than at pre-HWA. In particular, SWS, TUG, andhip torque were remarkably increased 3 weeks after THA and improved to almost the same levelsat follow-up. Maximum hip extension angle and hip ROM during gait were higher at post-HWAthan at pre-HWA. Maximum and minimum anterior pelvic tilt angles were lower at post-HWA thanat pre-HWA. The iEMG of the gluteus maximus and gluteus medius in the stance phase were lowerat post-HWA than preoperatively and at pre-HWA. CONCLUSIONS: In this case, the gait training usingHWA was safe and feasible, and could be effective for the early improvement of gait ability, hipfunction, and gait pattern after THA.
关键词
相关论文
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Trust Region Policy Optimization
John Schulman, Sergey Levine, Philipp Moritz 等 5 位作者
2015
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz 等 11 位作者
2012
Legged Robots That Balance
Marc H. Raibert, Ernest R. Tello
1986