Imageless, robotic-assisted total knee arthroplasty combined with a robotic tensioning system can help predict and achieve accurate postoperative ligament balance
Sami Shalhoub, Jeffrey M. Lawrence, John M. Keggi, Amber Randall, Jeffrey H. DeClaire, Christopher Plaskos
- 发表年份
- 2019
- 引用次数
- 72
- 访问权限
- 开放获取
摘要
BACKGROUND: Achieving balanced gaps is a key surgical goal in total knee arthroplasty, yet most methods rely on subjective surgeon feel and experience to assess and achieve knee balance intraoperatively. Our objective was to evaluate the ability to quantitatively plan and achieve a balanced knee throughout the range of motion using robotic-assisted instrumentation in a tibia-first, gap-balancing technique. METHODS: A robotic-assisted, gap-balancing technique was used in 121 consecutive knees. After resection of the proximal tibia, a computer-controlled tensioning device was inserted into the knee joint and the pre-femoral-resection knee gaps were acquired dynamically throughout flexion under controlled load. Predicted gap profiles were used to plan the femoral implant by adjusting the implant alignment and position within certain boundaries to achieve a balanced knee throughout the range of flexion. Femoral cuts were then made according to this plan using a miniature robotic-assisted cutting guide. The tensioning device used to measure the pre-femoral-resection gaps was then reinserted into the joint to quantify the final gap balance under known tension. The final gap profiles were then compared with the predictive gap plans. RESULTS: The overall root mean square error between the predicted and achieved gaps was 1.3 mm and 1.5 mm for the medial and lateral sides, respectively. Use of robotic assistance resulted in over 90% of knees having mediolateral balance within 2 mm across the flexion range. Gaps at 0° flexion were 2 mm smaller than the gaps at 90°. This difference decreased to less than 1 mm when comparing the tibiofemoral gaps at 10°, 45°, and 90°. CONCLUSIONS: Imageless, robotic-assisted total knee arthroplasty accurately predicts postoperative gaps before femoral resections. This allows surgeons to virtually plan femoral implant alignment and optimize gap balance throughout the range of motion. The accurate prediction of gaps throughout the arc of motion combined with precise, robotically assisted femoral resection produces accurate postoperative ligament balance consistently.
关键词
相关论文
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz 等 11 位作者
2012
Legged Robots That Balance
Marc H. Raibert, Ernest R. Tello
1986
Campbell-Walsh urology
Alan J. Wein editor-in-chief
2012