Accuracy and safety of a new robotic arm for both femoral and acetabular side in total hip arthroplasty: a cadaveric study
Xinzhe Lu, Zian Zhang, Wenzhe Wang, Hao Xu, Haining Zhang
- Year
- 2023
- Citations
- 2
- Access
- Open access
Abstract
BACKGROUND: To investigate the accuracy and safety of a newly constructed robotic arm which can cover the whole process of THA, we performed a series of robot-assisted total hip replacement on the cadaver. METHODS: Fifteen frozen cadaveric specimens (30 hips) were used for this study. In this investigation, united hip system and Longwell robotic-assisted system were used. The entire lower limb was CT scanned prior to surgery. The 3D model was produced based on CT data; the site of the prosthesis, including acetabular anteversion, inclination angle, and the position of femoral prosthesis, was planned. With the assistance of a robotic arm, the surgeon changed the parameters based on the preoperative plan and the actual condition during surgery, and completed the whole procedure. Following surgery, we measured the acetabular anteversion angle, acetabular inclination angle, femur anteversion angle, combined anteversion angle, stem angulation, and canal fill ratio. RESULTS: The parameters proved that the acetabular anteversion angle was 16.85 ± 3.00°, the acetabular inclination angle was 40.38 ± 5.37°, femur anteversion angle was 15.90 ± 9.01°, combined anteversion angle was 32.75 ± 9.03°, stem angulation was 1.84 ± 0.99°, and leg length discrepancy was 2.47 ± 1.43 mm. The canal fill ratio (CFR) of femoral prosthesis of osteotomy line in sagittal section is 99.72 ± 1.54% and in coronal section is 62.94 ± 8.91%; below osteotomy line 2.5 cm in sagittal section is 100.00% and in coronal section is 81.48 ± 12.94%; below osteotomy line 7.5 cm in sagittal section is 59.51 ± 12.94% and in coronal section is 89.79 ± 11.13%; femoral shaft isthmus in sagittal section is 56.41 ± 13.80% and in coronal section is 84.95 ± 15.17%. CONCLUSION: The accuracy and safety of this novel robotic arm are suitable for preparing both the acetabular and femoral sides, providing evidence for clinical trial.
Keywords
Related papers
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz +8 more
2012
Campbell-Walsh urology
Alan J. Wein editor-in-chief
2012
Stroke rehabilitation
Peter Langhorne, Julie Bernhardt, Gert Kwakkel
2011