Abstract

•Experienced prolonged intubation after robotic hysterectomy for endometrial cancer•Risk triad: Trendelenburg position, high pneumo-pressure, and excess hydration•Recognition of the risk triad is key to avoiding airway complications in robotic surgery.•Introduction of a 5-step method to prevent airway complications in robotic surgery.

Keywords

MedicineEndometrial cancerIntubationHysterectomyAirwayTrendelenburg positionRobotic surgerySurgeryPositive airway pressureCancer