Abstract

In this research work we investigated the accuracy of a standard industrial robot. We wanted to find out, how accurate an X-Ray Computed Tomography (CT) scan can be performed when using such a robot as a manipulator. The accuracy was measured using a laser-interferometer. The measured deviations were used to run an X-Ray simulation via Fraunhofer EZRT’s Scorpius X-Lab. Metrological analysis was performed as a measure for the quality of the simulated CT-scan. The metrological deviations reflect the feasible accuracy of a CT-scan in a real CT-setup.

Keywords

Computed tomographyIndustrial computed tomographyMetrologyRobotTomographyAccuracy and precisionInterferometryStandard deviationComputer scienceArtificial intelligence