Abstract
BACKGROUND: Precise and accurate glenoid preparation is important for the success of shoulder arthroplasty. Despite advancements in preoperative planning software and enabling technologies, most surgeons execute the procedure manually. Patient-specific instrumentation (PSI) facilitates accurate glenoid guide pin placement for cannulated reaming; however, few commercially available systems offer depth of reaming control. Robotic arm-assisted bone preparation has gained popularity in knee and hip arthroplasty, but at the present time there is limited information available on the use of robotics for shoulder arthroplasty. The purpose of this study was to compare glenoid preparation and final implant position using 3 techniques: manual, manual assisted with PSI, and robotic arm-assisted bone preparation. METHODS: Six shoulder surgeons participated in this study using 3 preparation techniques: (1) manual reaming, (2) manual reaming over a pin inserted using PSI, and (3) preparation using a robotic arm assist with an end-effector burr and haptic boundaries. Each surgeon randomly conducted each technique on 2 separate Bone Matrix glenoid models, for a total of 36 glenoid models tested. To compare the techniques, the final prepared Bone Matrix models underwent a computed tomographic scan with 3D virtual model generation. The prepared 3D virtual glenoid models were then compared to the preoperatively planned models. Parameters compared included deviations in version, inclination, anterior-posterior (AP) translation, superior-inferior (SI) translation, and depth of reaming. RESULTS: Regarding glenoid version with values reported as mean deviations from the preoperative plan, the robotic-assisted technique (1°) was significantly better than manual (9°, P < .001) and PSI (4°, P < .001) techniques at executing the preoperative plan. Regarding inclination, the robotic-assisted technique (2°) was significantly better than manual (9°, P = .003) but not significantly different than PSI (3°, P = .211). The robotic arm technique, with AP translation, resulted in significantly lower mean displacements (0.3 mm) than the manual technique (2 mm, P = .001) and the PSI technique (2 mm, P = .002). With SI translation, the robotic arm-assisted technique (0.7 mm) resulted in significantly lower mean displacements as compared to the manual (2 mm, P = .007) and PSI (1 mm, P = .011). The robotic arm-assisted technique (0.4 mm) did not result in significantly lower mean depth of reaming displacements compared to the manual technique (0.8 mm, P = .051) but did when compared to PSI (0.8 mm, P = .036). CONCLUSIONS: Glenoid preparation using a robotic arm with an end-effector burr and haptic boundaries was significantly better in its ability to execute a preoperatively planned implant position than manual preparation in 4 of the 5 glenoid metrics examined and was significantly better than PSI in 4 of the 5 glenoid metrics.
Keywords
Related papers
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
The Uncanny Valley [From the Field]
Masahiro Mori, Karl F. MacDorman, Norri Kageki
2012
Measurement Instruments for the Anthropomorphism, Animacy, Likeability, Perceived Intelligence, and Perceived Safety of Robots
Christoph Bartneck, Dana Kulić, Elizabeth A. Croft +1 more
2008
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz +8 more
2012