Home /Research /Upgrade to the Birmingham Irradiation Facility
OTHER

Upgrade to the Birmingham Irradiation Facility

P. Dervan, S. T. French, P. Hodgson, Hector Marin-Reyes, K. A. Parker, John Wilson, M. J. Baca

Year
2015
Citations
9

Abstract

The Birmingham Irradiation Facility was developed in 2013 at the University of Birmingham using the Medical Physics MC40 cyclotron. It can achieve High Luminosity LHC (HL-LHC) fluences of 1015 (1 MeV neutron equivalent (neq)) cm−2 in 80 s with proton beam currents of 1 μA and so can evaluate effectively the performance and durability of detector technologies and new components to be used for the HL-LHC. Irradiations of silicon sensors and passive materials can be carried out in a temperature controlled cold box which moves continuously through the homogenous beamspot. This movement is provided by a pre-configured XY-axis Cartesian robot scanning system. In 2014 the cooling system and cold box were upgraded from a recirculating glycol chiller system to a liquid nitrogen evaporative system. The new cooling system achieves a stable temperature of −50 °C in 30 min and aims to maintain sub-0 °C temperatures on the sensors during irradiations. This paper reviews the design, development, commissioning and performance of the new cooling system.

Keywords

UpgradeCyclotronLarge Hadron ColliderNuclear engineeringWater coolingIrradiationMaterials scienceNeutronPhysicsNuclear physics