首页 /研究 /Analytical Study on Curved Box Girder Bridges with Minimum Horizontal Stiffeners
OTHER

Analytical Study on Curved Box Girder Bridges with Minimum Horizontal Stiffeners

Junichi Adachi, Takashi Yamaguchi, Kohei Funayama, Shintaro Arai, Michiaki Takao

发表年份
2019
引用次数
3

摘要

<p>Curved box girder bridges are widely used in viaducts in urban areas, as well as highway junctions. In fabricating curved box girders, automatic welding robots cannot be applied to welding of horizontal stiffeners to the web panel due to the girder curvature and manufacturing costs increase.<span>Elimination or reduction of the number of horizontal stiffeners is desirable. In this study,</span>FE analysis was carried out varying the curvature and the width-thickness ratio of the structural components as structural parameters to propose the curved box girder bridges without horizontal stiffeners in the web panel. In order to evaluate<span>the ultimate strength, the collapse mode (buckling of lower flange, web panel or stiffeners) has been clarified considering the</span>design sectional forces such as torsional moment, bending moment and shearing force.</p><p>From the results, it was found that the curvature has little influence on the bending buckling strength of the web panels. Even if the horizontal stiffeners are eliminated, the ultimate strength doesn’t decrease until compressive flange buckling occurs. It is concluded that the ultimate strength is governed by the buckling of the compressive flange, even when the bending buckling occurs in the web panel.</p>

关键词

FlangeStructural engineeringBucklingGirderCurvatureSpan (engineering)WeldingEngineeringBending momentBending

相关论文

查看 OTHER 分类全部论文