Robotically Controlled Pattern Measurements of 60 GHz Phased Array Antenna
Carmen Matos, Jiantong Li, Nima Ghalichechian
- 发表年份
- 2019
- 引用次数
- 5
摘要
The characterization of antenna radiation patterns in the millimeter wave band are particularly challenging. This is due to the fact that a misalignment of just a few millimeters between the probe and the antenna can generate substantial measurement errors. This paper describes a strategy to reduce measurement errors by introducing a highly precise measurement system using a 6-axis small robotic arm to characterize the performance of a phased array antenna operating at 60 GHz. The position accuracy of the robotic arm itself is approximately 20 μm and a maximum far field distance of approximately 380 mm can be achieved. The robot is programmed to perform a spherical trajectory around the array with stops every 0.5° along the path to gather the measured gain. It operates continuously by communicating with a computer, which triggers the network analyzer at preprogrammed locations. The system is tested initially using two horn antennas as the antenna under test (AUT), and the results are presented.