Click-on fluorescence detectors: using robotic surgical instruments to characterize molecular tissue aspects
Matthias N. van Oosterom, Sven I. van Leeuwen, Elio Mazzone, Paolo Dell’Oglio, Tessa Buckle, Florian van Beurden, Michael Boonekamp, Huybert van de Stadt, Kevin Bauwens, Hervé Simon, Pim J. van Leeuwen, H.G. Van Der Poel, Fijs W. B. van Leeuwen
- 发表年份
- 2022
- 引用次数
- 11
- 访问权限
- 开放获取
摘要
Abstract Fluorescence imaging is increasingly being implemented in surgery. One of the drawbacks of its application is the need to switch back-and-forth between fluorescence- and white-light-imaging settings and not being able to dissect safely under fluorescence guidance. The aim of this study was to engineer ‘click-on’ fluorescence detectors that transform standard robotic instruments into molecular sensing devices that enable the surgeon to detect near-infrared (NIR) fluorescence in a white-light setting. This NIR-fluorescence detector setup was engineered to be press-fitted onto standard forceps instruments of the da Vinci robot. Following system characterization in a phantom setting (i.e., spectral properties, sensitivity and tissue signal attenuation), the performance with regard to different clinical indocyanine green (ICG) indications (e.g., angiography and lymphatic mapping) was determined via robotic surgery in pigs. To evaluate in-human applicability, the setup was also used for ICG-containing lymph node specimens from robotic prostate cancer surgery. The resulting Click-On device allowed for NIR ICG signal identification down to a concentration of 4.77 × 10 –6 mg/ml. The fully assembled system could be introduced through the trocar and grasping, and movement abilities of the instrument were preserved. During surgery, the system allowed for the identification of blood vessels and assessment of vascularization (i.e., bowel, bladder and kidney), as well as localization of pelvic lymph nodes. During human specimen evaluation, it was able to distinguish sentinel from non-sentinel lymph nodes. With this introduction of a NIR-fluorescence Click-On sensing detector, a next step is made towards using surgical instruments in the characterization of molecular tissue aspects.
关键词
相关论文
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz 等 11 位作者
2012
Campbell-Walsh urology
Alan J. Wein editor-in-chief
2012
Stroke rehabilitation
Peter Langhorne, Julie Bernhardt, Gert Kwakkel
2011