首页 /研究 /Fault Tree Analysis for an Inspection Robot in a Nuclear Power Plant
OTHER

Fault Tree Analysis for an Inspection Robot in a Nuclear Power Plant

Thomas A. Ferguson, Lixuan Lu

发表年份
2017
引用次数
13
访问权限
开放获取

摘要

The life extension of current nuclear reactors has led to an increasing demand on inspection and maintenance of critical reactor components that are too expensive to replace. To reduce the exposure dosage to workers, robotics have become an attractive alternative as a preventative safety tool in nuclear power plants. It is crucial to understand the reliability of these robots in order to increase the veracity and confidence of their results. This study presents the Fault Tree (FT) analysis to a coolant outlet piper snake-arm inspection robot in a nuclear power plant. Fault trees were constructed for a qualitative analysis to determine the reliability of the robot. Insight on the applicability of fault tree methods for inspection robotics in the nuclear industry is gained through this investigation.

关键词

Fault tree analysisNuclear power plantRobotReliability engineeringReliability (semiconductor)Nuclear powerRoboticsArtificial intelligenceComputer scienceEngineering