Kinematic Calibration of a Parallel 2-UPS/RRR Ankle Rehabilitation Robot
Mingjie Dong, Yuan Kong, Jianfeng Li, Wenpei Fan
- 发表年份
- 2020
- 引用次数
- 25
- 访问权限
- 开放获取
摘要
In order to better perform rehabilitation training on the ankle joint complex in the direction of dorsiflexion/plantarflexion and inversion/eversion, especially when performing the isokinetic muscle strength exercise, we need to calibrate the kinematic model to improve its control precision. The ankle rehabilitation robot we develop is a parallel mechanism, with its movements in the two directions driven by two linear motors. Inverse solution of positions is deduced and the output lengths of the two UPS kinematic branches are calibrated in the directions of dorsiflexion, plantarflexion, inversion, and eversion, respectively. Motion of each branch in different directions is fitted in high-order form according to experimental data. Variances, standard deviation, and goodness of fit are taken into consideration when choosing the best fitting curve, which ensures that each calibration can match the most appropriate fitting curve. Experiments are conducted to verify the effectiveness of the kinematic calibration after finishing the calibration, and the errors before and after calibration of the two kinematic chains in different directions are compared, respectively, which shows that the accuracy after calibration has been significantly improved.