首页 /研究 /Case report of a robotic-assisted laparoscopic repair of a giant incarcerated recurrent inguinal hernia containing bladder and ureters
SURGICAL

Case report of a robotic-assisted laparoscopic repair of a giant incarcerated recurrent inguinal hernia containing bladder and ureters

Lawrence N. Cetrulo, Justin D. Harmon, Jorge Ortiz, Daniel Canter, Amit Joshi

发表年份
2014
引用次数
27

摘要

BACKGROUND: Robotic surgery is particularly useful in pelvic procedures, such as prostatectomy and low anterior resection. The paper describes a robotic-assisted repair of a giant bladder- and ureter-containing incarcerated inguinal hernia. METHODS AND RESULTS: A 53-year-old man had previously undergone repair of a left inguinal hernia. He presented to our clinic complaining of difficulty urinating and a large bulge in his left scrotum. CT revealed a giant left scrotal hernia containing the bladder and both ureters. The patient underwent robotic-assisted laparoscopic repair. The bladder and both ureters were carefully dissected free from the scrotum, while preserving the testicle and spermatic cord. A 6×4 inch pre-peritoneal polyester composite mesh was then used to repair the defect. CONCLUSION: Incarcerated, recurrent inguinal hernias are challenging repairs. Robotic-assisted repair allows for fine dissection, and is an excellent alternative to open surgery for a difficult inguinal hernia.

关键词

MedicineScrotumSurgerySpermatic cordDissection (medical)HerniaInguinal herniaInguinal canalGeneral surgery