Stereotactic and Robotic Minimally Invasive Thermal Ablation of Malignant Liver Tumours - A Systematic Review and Meta-Analysis
Pascale Tinguely, Iwan Paolucci, Simeon J. S. Ruiter, Stefan Weber, Koert de Jong, Daniel Candinas, Jacob Freedman, Jennie Engstrand
- Year
- 2020
- Citations
- 2
- Access
- Open access
Abstract
Abstract Background: Stereotactic navigation techniques aim to enhance treatment precision and safety in minimally invasive thermal ablation of liver tumours. We qualitatively reviewed and quantitatively summarised the available literature on procedural and clinical outcomes after stereotactic navigated ablation of malignant liver tumours. Methods: A systematic literature search was performed on procedural and clinical outcomes when using stereotactic or robotic navigation for laparoscopic or percutaneous thermal ablation. The online databases Medline, Embase and Cochrane Library were searched. Endpoints included targeting accuracy, procedural efficiency and treatment efficacy outcomes. Meta-analysis including subgroup analyses were performed. Results: Thirty-four studies (2 randomised controlled trials, 3 prospective cohort studies, 29 case series) were qualitatively analysed and 22 studies included for meta-analysis. Weighted average lateral targeting error was 3.7mm (CI 3.2,4.2), with all four comparative studies showing enhanced targeting accuracy compared to free-hand targeting. Weighted average overall complications, major complications and mortality were 11.4% (6.7, 16.1), 3.4% (2.1, 5.1) and 0.8% (0.5, 1.3). Pooled estimates of primary technique efficacy were 94% (89, 97) if assessed at 1 – 6 weeks and 90% (87, 93) if assessed at 6 – 12 weeks post ablation, with significant remaining between-study heterogeneity. Pooled odds ratio of primary technique efficacy for stereotactic versus free-hand targeting was 1.9 (1.2, 3.2)(n = 6 studies). Conclusions: Advances in stereotactic navigation technologies allow highly precise and safe tumour targeting, potentially leading to enhanced early treatment efficacy. The use of varying definitions and terminology limit comparability of safety and efficacy among studies, highlighting the crucial need for further standardization of follow-up definitions.
Keywords
Related papers
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz +8 more
2012
Campbell-Walsh urology
Alan J. Wein editor-in-chief
2012
Stroke rehabilitation
Peter Langhorne, Julie Bernhardt, Gert Kwakkel
2011