Home /Research /A Performance Evaluation of a Notebook PC under a High Dose-Rate Gamma Ray Irradiation Test
OTHER

A Performance Evaluation of a Notebook PC under a High Dose-Rate Gamma Ray Irradiation Test

Jai Wan Cho, Kyung Min Jeong

Year
2014
Citations
3
Access
Open access

Abstract

We describe the performance of a notebook PC under a high dose-rate gamma ray irradiation test. A notebook PC, which is small and light weight, is generally used as the control unit of a robot system and loaded onto the robot body. Using TEPCO’s CAMS (containment atmospheric monitoring system) data, the gamma ray dose rate before and after a hydrogen explosion in reactor units 1–3 of the Fukushima nuclear power plant was more than 150 Gy/h. To use a notebook PC as the control unit of a robot system entering a reactor building to mitigate the severe accident situation of a nuclear power plant, the performance of the notebook PC under such intense gamma-irradiation fields should be evaluated. Under a similar dose-rate (150 Gy/h) gamma ray environment, the performances of different notebook PCs were evaluated. In addition, a simple method for a performance evaluation of a notebook PC under a high dose-rate gamma ray irradiation test is proposed. Three notebook PCs were tested to verify the method proposed in this paper.

Keywords

Nuclear power plantGamma rayIrradiationDose rateRobotSimulationComputer scienceNuclear engineeringEngineeringRadiochemistry