Robotic-guided direct transtemporal embolization of an indirect carotid cavernous fistula
Patrick J. Karas, Jae Eun Lee, Thomas S. Frank, Frances Morden, Hashem Shaltoni, Peter Kan
- Year
- 2023
- Citations
- 4
Abstract
A middle-aged patient presented with right-sided chemosis, exophthalmos, and progressive visual loss. Digital subtraction angiography revealed a type D carotid-cavernous fistula (CCF). Transarterial embolization through the internal maxillary artery was unsuccessful, and there was no venous access to the CCF. A robotic-guided direct transtemporal embolization of the CCF with Onyx was performed, resulting in successful fistula obliteration and symptom resolution. This is the first reported case of a robotic-guided direct transcranial CCF embolization. We include a technical video that demonstrates this procedure (Supplemental File 1).