MIRRORS ICG: Perfusion Assessment Using Indocyanine Green (ICG) Peritoneal Angiography during Robotic Interval Cytoreductive Surgery for Advanced Ovarian Cancer
Christina Uwins, Agnieszka Michael, Simon S. Skene, Hersha Patel, Patricia Ellis, Jayanta Chatterjee, Anil Tailor, Simon Butler‐Manuel
- Year
- 2024
- Citations
- 5
Abstract
Indocyanine green (ICG) is a fluorescent dye used for sentinel lymph node assessment and the assessment of perfusion in skin flaps and bowel anastomoses. ICG binds serum proteins and behaves as a macromolecule in the circulation. Tumour tissue has increased vascular permeability and reduced drainage, causing macromolecules to accumulate within it. MIRRORS ICG is designed to determine whether indocyanine green (ICG) helped identify metastatic deposits in women undergoing robotic interval cytoreductive surgery for advanced-stage (3c+) ovarian cancer. Peritoneal surfaces of the abdominal and pelvic cavity were inspected under white light and near-infrared light (da Vinci Si and Xi Firefly Fluorescence imaging, Intuitive Surgical Inc.) following intravenous injection of 20 mg ICG in sterile water. Visibly abnormal areas were excised and sent to histopathology, noting IGC positivity. In total, 102 biopsies were assessed using ICG. Intravenous ICG assessment following neoadjuvant chemotherapy had a sensitivity of 91.1% (95% CI [82.6-96.4%]), a specificity of 13.0% (95% CI [2.8-33.6%]), a positive predictive value of 78.3% (95% CI [68.4-86.2%]), and a negative predictive value of 30.0% (95% CI [6.7-65.2%]) False-positive samples were seen in 9/20 patients. Psammoma bodies were noted in the histopathology reports of seven of nine of these patients with false-positive results, indicating that a tumour had been present (chemotherapy-treated disease). This study demonstrates the appearance of metastatic peritoneal deposits during robotic cytoreductive surgery following the intravenous administration of ICG in women who have undergone neoadjuvant chemotherapy for stage 3c+ advanced ovarian cancer. A perfusion assessment using indocyanine green (ICG) peritoneal angiography during robotic interval cytoreductive surgery for advanced ovarian cancer did not clinically improve metastatic disease identification in patients with high-volume disease. The use of ICG in patients with excellent response to chemotherapy where few tumour deposits remained shows some promise. The potential of molecular imaging to enhance precision surgery and improve disease identification using the robotic platform is a novel avenue for future research.
Keywords
Related papers
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz +8 more
2012
Campbell-Walsh urology
Alan J. Wein editor-in-chief
2012
Stroke rehabilitation
Peter Langhorne, Julie Bernhardt, Gert Kwakkel
2011