Quantification of surgical workflow during robotic proctectomy
Mishal Gillani, Manali Rupji, Courtney L. Devin, Lilia Purvis, Terrah J. Paul Olson, Anthony Jarc, Mallory Shields, Yuan Liu, Seth A. Rosen
- Year
- 2024
- Citations
- 6
Abstract
BACKGROUND: Surgical workflow assessments offer insight regarding procedure variability. We utilised an objective method to evaluate workflow during robotic proctectomy (RP). METHODS: We annotated 31 RPs and used Spearman's correlation to measure the correlation of step time and step visit frequency with console time (CT) and total operative time (TOT). RESULTS: Strong correlations were seen with CT and step times for inferior mesenteric vein dissection and ligation (ρ = 0.60, ρ = 0.60), lateral-to-medial splenic flexure mobilisation (SFM) (ρ = 0.63), left rectal dissection (ρ = 0.64) and mesorectal division (ρ = 0.71). CT correlated strongly with medial-to-lateral (ρ = 0.75) and supracolic SFM visit frequency (ρ = 0.65). TOT correlated strongly with initial exposure time (ρ = 0.60), and medial-to-lateral (ρ = 0.67) and supracolic SFM visit frequency (ρ = 0.65). CONCLUSION: This study correlates surgical steps with CT and TOT through standardised annotation, providing an objective approach to quantify workflow.