Home /Research /SU‐E‐T‐422: Lung SBRT Using Cyberknife: Technique and Treatment Outcome
SURGICAL

SU‐E‐T‐422: Lung SBRT Using Cyberknife: Technique and Treatment Outcome

Tithi Biswas, B. Holland, Julian Rosenman, Tarun K. Podder

Year
2012
Citations
7

Abstract

PURPOSE: At East Carolina University, we have been treating primary and secondary lung cancers with Cyberknife stereotactic body radiotherapy (CK- SBRT) since February 2009. Till October 2011, we have treated a total of 79 patients (83 sites). In this study, we present our experience in CK-SBRT and clinical outcome of the treated patients. METHODS: Of the 79 patients, 43 were female; age of the whole patient population ranged 33.2-89.7yrs (median=73.2yrs). Patients treated for primary lung cancer (n=57) had severe chronic obstructive pulmonary disease (COPD) and were not surgical candidates. Cyberknife robotic system with tracking techniques (Synchrony=52, XsiteLung=22, XsightSpine=5) were used. Majority of the patient (n=52) had multiple gold fiducials placed (1-6 placed; 1-4 tracked per patient) either percutaneously or bronchoscopically. CT images were used for dosimetric planning, by medical physicists, using Cyberknife MultiPlan software. Prescription doses were 25Gy-55Gy in 3-5 fractions (mean=48.2Gy, median=50Gy); doses were prescribed mainly to 80% isodoseline (range=75-96%, mean=81.4%). PTV margin varied from 0-7mm (mean±SD=3.2±1.4mm), based on the tumor locations; breathing patterns and cancer type. Dosimetric coverage of GTV and PTV were (mean±SD): 97.8±5% and 94.7±6.9%, respectively. The treatment response was assessed using either a CT or a PET scan or both. RESULTS: The median follow up was 13.1months (range 0.3-31.9 months). Overall response rate was 98.8% (CR=73.5%). Local failure free survival at one year was 84% for primary (n=57), 76% for recurrent (n=16) lung cancer and 100% for metastatic (n=10) tumors. The toxicity rate was low with one patient reported to have chest wall pain and one patient developed grade 3-4 radiation pneumonitis. CONCLUSIONS: In most of the cases tight PTV margins were used. Since the prescriptions were at 80% isodeose line with more than 94% PTV coverage, the treatment outcome appeared reasonable. Further study relating PTV margin, dosimetric coverage, and treatment outcome is in progress.

Keywords

CyberknifeMedicineNuclear medicineLung cancerRadiation therapyPopulationDosimetryRadiation treatment planningRadiologyFiducial marker

Related papers

Browse all SURGICAL papers