Robot-assisted intravertebral augmentation corrects local kyphosis more effectively than a conventional fluoroscopy-guided technique
Sultan Alsalmi, Cyrille Capel, Louis Chenin, Johann Peltier, Michel Lefranc
- Year
- 2019
- Citations
- 12
- Access
- Open access
Abstract
OBJECTIVEIntravertebral augmentation (IVA) is a reliable minimally invasive technique for treating Magerl type A vertebral body fractures. However, poor correction of kyphotic angulation, the risk of cement leakage, and significant exposure to radiation (for the surgeon, the operating room staff, and the patient) remain significant issues. The authors conducted a study to assess the value of robot-assisted IVA (RA-IVA) for thoracolumbar vertebral body fractures.METHODSThe authors performed a retrospective, single-center study of patients who had undergone RA-IVA or conventional fluoroscopy-guided IVA (F-IVA) for thoracolumbar vertebral body fractures. Installation and operating times, guidance accuracy, residual local kyphosis, degree of restoration of vertebral body height, incidence of cement leakage, rate of morbidity, length of hospital stay, and radiation-related data were recorded.RESULTSData obtained in 30 patients who underwent RA-IVA were compared with those obtained in 30 patients who underwent F-IVA during the same period (the surgical indications were identical, but the surgeons were different). The mean ± SD installation time in the RA-IVA group (24 ± 7.5 minutes) was significantly shorter (p = 0.005) than that in the F-IVA group (26 ± 8 minutes). The mean operating time for the RA-IVA group (52 ± 11 minutes) was significantly longer (p = 0.026) than that for the F-IVA group (30 ± 11 minutes). All RA-IVAs and F-IVAs were Ravi's scale grade A (no pedicle breach). The mean degree of residual local kyphosis (4.7° ± 3.15°) and the percentage of vertebral body height restoration (63.6% ± 21.4%) were significantly better after RA-IVA than after F-IVA (8.4° ± 5.4° and 30% ± 34%, respectively). The incidence of cement leakage was significantly lower in the RA-IVA group (p < 0.05). The mean length of hospital stay after surgery was 3.2 days for both groups. No surgery-related complications occurred in either group. With RA-IVA, the mean radiation exposure was 438 ± 147 mGy × cm for the patient and 30 ± 17 mGy for the surgeon.CONCLUSIONSRA-IVA provided better vertebral body fracture correction than the conventional F-IVA. However, RA-IVA requires more time than F-IVA.
Keywords
Related papers
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz +8 more
2012
Campbell-Walsh urology
Alan J. Wein editor-in-chief
2012
Stroke rehabilitation
Peter Langhorne, Julie Bernhardt, Gert Kwakkel
2011