Optimizing Robot-Assisted Surgery Suture Plans to Avoid Joint Limits and Singularities
Brijen Thananjeyan, Ajay Kumar Tanwani, Jessica Ji, Danyal Fer, Vatsal Patel, Sanjay Krishnan, Ken Goldberg
- Year
- 2019
- Citations
- 15
Abstract
Laparoscopic robots such as the da Vinci Research Kit encounter joint limits and singularities during procedures, leading to errors and prolonged operating times. We propose the Circle Suture Placement Problem to optimize the location and direction of four evenly-spaced stay sutures on surgical mesh for robot-assisted hernia surgery. We present an algorithm for this problem that runs in 0.4 seconds on a desktop equipped with commodity hardware. Simulated results integrating data from expert surgeon demonstrations suggest that optimizing over both suture position and direction increases dexterity reward by 11%-57% over baseline algorithms that optimize over either suture position or direction only.
Keywords
Related papers
Statistical Learning Theory
Yuhai Wu, Vladimir Vapnik
1999
Artificial intelligence: a modern approach
1995
Applied Nonlinear Control
Jean-Jacques Slotine, Weiping Li
1991
A new optimizer using particle swarm theory
R.C. Eberhart, James Kennedy
2002