In vitro and in vivo accuracy of autonomous robotic vs. fully guided static computer‐assisted implant surgery
He Jin, Qinmeng Zhang, Xueting Wang, Mengdie Fu, Hui Zhang, Luyao Song, Rui Pu, Zhiwei Jiang, Guoli Yang
- Year
- 2024
- Citations
- 26
Abstract
OBJECTIVES: To assess the accuracy of autonomous robotic and fully guided static computer-assisted implant surgery (sCAIS) performed on models and patients. MATERIALS AND METHODS: This study was divided into in vitro and in vivo sections. In vitro, 80 operators were assigned to two groups randomly. Forty operators performed forty autonomous robotic implant (ARI group) surgeries and the remaining forty operators carried out forty fully guided sCAIS (FGI group) surgeries on maxillary models, respectively. Each operator placed an implant in one maxillary model. In vivo, 60 patients with 113 implants from 2019 to 2023 (ARI group: 32 patients, 58 implants; FGI group: 28 patients, 55 implants) receiving implant surgeries were incorporated in this retrospective research. The preoperative and postoperative cone beam computer tomographs (CBCTs) were utilized to estimate the linear deviations and angular deviations in two-dimensional (2D) and three-dimensional (3D) space. The Pearson's chi-square test, Shapiro-Wilk test, Student's t test, Mann-Whitney U test and mixed models were applied, and p <0.05 was considered statistically significant. RESULTS: In vitro, a total of 80 implants were enrolled and significant differences were found between the two groups (p < 0.001): The 3D deviation at the platform of ARI and FGI group was 0.58 ± 0.60 mm and 1.50 ± 1.46 mm, respectively, at the apex was 0.58 ± 0.60 mm and 1.78 ± 1.35 mm, respectively, and angle was 1.01 ± 0.87° and 2.93 ± 1.59°, respectively. Also, except for mesiodistal deviation at the implant platform, the rest linear and angular deviations in the ARI group were significantly lower than those in the FGI group in 2D space (p < 0.001). In vivo, a significantly lower mean of angular deviation (0.95 ± 0.50°, p < 0.001) and the linear deviation at both platform (0.45 ± 0.28 mm, p < 0.001) and apex (0.47 ± 0.28 mm, p < 0.001) were observed in ARI group when compared to the FGI group (4.31 ± 2.60°; 1.45 ± 1.27 mm; 1.77 ± 1.14 mm). CONCLUSIONS: The use of autonomous robotic technology showed significantly higher accuracy than the fully guided sCAIS.
Keywords
Related papers
Fractional Differential Equations
Igor Podlubný
2025
Fractional Brownian Motions, Fractional Noises and Applications
Benoît B. Mandelbrot, John W. Van Ness
1968
Closed-form solution of absolute orientation using unit quaternions
Berthold K. P. Horn
1987
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019