Robot‐assisted Percutaneous Transfacet Screw Fixation Supplementing Oblique Lateral Interbody Fusion Procedure: Accuracy and Safety Evaluation of This Novel Minimally Invasive Technique
Jingye Wu, Qiang Yuan, Yajun Liu, Yuqing Sun, Yong Zhang, Wei Tian
- Year
- 2019
- Citations
- 38
- Access
- Open access
Abstract
OBJECTIVES: Percutaneous transfacet screw fixation (pTSF) is a minimally invasive posterior fixation technique supplementing oblique lateral interbody fusion (OLIF) for lumbar spinal disorders. Accurate screw insertion is difficult to achieve and technically demanding under 2-D fluoroscopy. Recently developed robot-assisted spinal surgery demonstrated a high level of accuracy of pedicle screw insertion and a low complication rate. No published study has reported this combination technique. The aim of our study was to evaluate the accuracy and safety properties of the combination of both minimally invasive techniques: robot-assisted pTSF supplementing the OLIF procedure. METHODS: This was an experimental and prospective study. Selected consecutive patients with lumbar degenerative disorders received robot-assisted pTSF supplementing the OLIF procedure using the TianJi Robot system operated by one senior surgeon from March to October 2018. The accuracy of screw insertion and perioperative screw-related complications were evaluated. Assessment of the accuracy of screw insertion included intraoperative robotic guidance accuracy and incidence of screw encroachments. Intraoperative robotic guidance accuracy referred to translational and angular deviations of screws, which were assessed by comparing the planned and actual screw trajectories guided by the robot on reconstructed images using TianJi Robot Planning Software. Screw encroachments were evaluated on postoperative CT images and classified by a grading system (A, excellent; B, good; C, poor). Screw-related complications including intraoperative pin skidding, screw malposition and adjustment, together with postoperative neurological symptoms that correlated with screw malposition were recorded. RESULTS: level fixation. The average surgical time was 3.3 h (SD, 0.8 h). The mean blood loss was 90 mL (SD, 32 mL). Intraoperative guidance accuracy showed 1.09 ± 0.17 mm (ranging from 0.75 to 1.22 mm) translational deviation and 2.17° ± 0.39° (ranging from 1.47° to 2.54°) angular deviation. The gradings of screw encroachment were: 17 screws (71%) with Grade A, 6 screws (25%) with Grade B, and 1 screw (4%) with Grade C. Only one pin skidding occurred intraoperatively and revised subsequently. No postoperative neurological complications were found. CONCLUSION: Our preliminary study of robot-assisted pTSF supplementing the OLIF procedure showed a high level of accuracy for screw insertion and this minimally invasive combination technique was found to be a feasible and safe procedure.
Keywords
Related papers
Statistical Learning Theory
Yuhai Wu, Vladimir Vapnik
1999
Artificial intelligence: a modern approach
1995
Applied Nonlinear Control
Jean-Jacques Slotine, Weiping Li
1991
A new optimizer using particle swarm theory
R.C. Eberhart, James Kennedy
2002