Home /Research /Single‐site robotic cholecystectomy: efficiency and cost analysis
SURGICAL

Single‐site robotic cholecystectomy: efficiency and cost analysis

Francis A. Buzad, Louis M. Corne, Thomas C. Brown, Randy Fagin, April E. Hebert, Charles A. Kaczmarek, Angie N. Pack, Thomas N. Payne

Year
2013
Citations
68

Abstract

BACKGROUND: Single-incision surgery has gained in popularity, and the recent development of specialized robotic and laparoscopic instruments may remove some of the ergonomic and technical difficulties associated with this approach. However, questions of cost and efficiency remain. METHODS: We prospectively collected perioperative outcome and efficiency (operative time, case volume) data for our single-site robotic cholecystectomy cases and retrospectively reviewed data for our single-incision laparoscopic cholecystectomy cases. RESULTS: There were no differences in patient characteristics or perioperative outcomes between the robotic (n = 20) and laparoscopic (n = 10) groups; operative times were equivalent (84.6 vs 85.5 min; p = 0.8737) and blood loss and complications were minimal. There was a higher robotic case volume, with an average of two robotic cases (range 1-4)/day vs one/day for laparoscopic cases (range 1-1; p = 0.0306). Streamlined instrument costs were essentially equivalent. CONCLUSIONS: Robotic single-site cholecystectomy is a safe, cost-effective alternative to single-incision laparoscopic cholecystectomy in a robot-existing model.

Keywords

PerioperativeCholecystectomyLaparoscopic cholecystectomyBlood lossMedicineSurgeryRobotic surgeryGeneral surgery