Home /Research /3-D Ultrasound-Guided Robotic Needle Steering in Biological Tissue
OTHER

3-D Ultrasound-Guided Robotic Needle Steering in Biological Tissue

Troy K. Adebar, Ashley E. Fletcher, Allison M. Okamura

Year
2014
Citations
98

Abstract

Robotic needle steering systems have the potential to greatly improve medical interventions, but they require new methods for medical image guidance. Three-dimensional (3-D) ultrasound is a widely available, low-cost imaging modality that may be used to provide real-time feedback to needle steering robots. Unfortunately, the poor visibility of steerable needles in standard grayscale ultrasound makes automatic segmentation of the needles impractical. A new imaging approach is proposed, in which high-frequency vibration of a steerable needle makes it visible in ultrasound Doppler images. Experiments demonstrate that segmentation from this Doppler data is accurate to within 1-2 mm. An image-guided control algorithm that incorporates the segmentation data as feedback is also described. In experimental tests in ex vivo bovine liver tissue, a robotic needle steering system implementing this control scheme was able to consistently steer a needle tip to a simulated target with an average error of 1.57 mm. Implementation of 3-D ultrasound-guided needle steering in biological tissue represents a significant step toward the clinical application of robotic needle steering.

Keywords

Computer visionArtificial intelligenceUltrasoundSegmentationComputer scienceVisibilityGrayscaleRobot3D ultrasoundModality (human–computer interaction)

Related papers