SURGICAL
Ergonomic use of the fourth arm to oversew the dorsal vascular complex ( <scp>DVC</scp> ) during robot‐assisted laparoscopic prostatectomy ( <scp>RALP</scp> )
O. Karim, Amrith Raj Rao, Emma Marsdin, Rajesh Kavia, Arie Parnham, Hanif Motiwala, Marc Laniado
- 发表年份
- 2012
- 引用次数
- 2
摘要
OBJECTIVE: To demonstrate an ergonomic fourth arm technique to oversew the dorsal vascular complex (DVC) during robot-assisted laparoscopic prostatectomy (RALP). PATIENTS AND METHODS: Balloon of a Foley catheter inflated in the bulbar urethra. Fourth arm cranial traction via suture in the tip of the catheter. DVC oversewn under direct vision. RESULTS: Oversew of DVC with minimal patient-side surgical assistance. About a 50% reduction in apical positive margin rate. CONCLUSION: A useful, ergonomic method of oversewing the DVC during RALP.