How Does Free Rod-Sliding Affect the Posterior Instrumentation for a Dynamic Stabilization Using a Bovine Calf Model?
Martin Schulze, René Hartensuer, Dominic Gehweiler, Thomas Vordemvenne, Michael J. Raschke, Frank Trautwein, Frank Heuer
- 发表年份
- 2014
- 引用次数
- 3
摘要
STUDY DESIGN: A biomechanical cadaveric study in lumbar calf spine. OBJECTIVE: Evaluation of the effects of selected degrees of freedom (df) on the dynamic stabilization of the spine in terms of segmental range of motion (RoM), center of rotation (CoR), and implant loadings. SUMMARY OF BACKGROUND DATA: For dorsal stabilization, rigid implant systems are becoming increasingly complemented by numerous dynamic systems based on pedicle screws and varying df. However, it is still unclear which df is most suitable to accomplish a physiologically related dynamic stabilization, and which loadings are induced to the implants. Human and calf specimens are reported to show certain similarities in their biomechanics. Young healthy calf specimens are not degenerated and show less interindividual differences than elderly human specimens. However, the existing differences between species limit the conclusions in a preclinical setting. METHODS: Six calf specimens from level L3-L4 were analyzed in flexion and extension with a 6-df robotic spine simulator. A clinical functional radiological examination tool was used and parameters such as RoM, CoR, and implant loadings were determined for 6 configurations: (1) intact, (2) defect, (3) rigid fixation, (4) free craniocaudal (CC) rod-sliding, (5) free polyaxiality, and (6) combined free rod-sliding and free polyaxiality. The location of the CoR was determined relative to vertebral body dimensions. A CoR repositioning was defined as sufficient when its median differed less than 5% of the vertebral body dimensions. RESULTS: Free rod-sliding in the CC direction restored the CoR from the defect back to the intact condition. The RoM could be significantly reduced to approximately 1/2 of the intact condition. Compared with the rigid condition, the implant bending moments increased from 0.3/-0.8 Nm (flexion/extension) to 1.3/-1.2 Nm for the free CC rod-sliding condition. CONCLUSION: Free CC rod-sliding restores the intact conditions of the tested kinematic parameters most suitably and at the same time reduces the RoM. Stabilization toward the intact condition could decrease the risk of stress shielding and the progress of segment degeneration. LEVEL OF EVIDENCE: N/A.
关键词
相关论文
Statistical Learning Theory
Yuhai Wu, Vladimir Vapnik
1999
Fractional Differential Equations
Igor Podlubný
2025
Applied Nonlinear Control
Jean-Jacques Slotine, Weiping Li
1991
Genetic Programming: On the Programming of Computers by Means of Natural Selection
John R. Koza
1992