Robotic-Assisted unicompartmental knee arthroplasty restores native joint line height and reduces alignment outliers
George Mihai Avram, Horia Tomescu, Randa Elsheikh, Giacomo Pacchiarotti, Octav Russu, Vlad Rusu, Dennis Cicio, A Nowakowski, Michael T. Hirschmann, Vlad Predescu
- 发表年份
- 2025
- 引用次数
- 3
- 访问权限
- 开放获取
摘要
PURPOSE: Registry data suggests that robotic-assisted unicompartmental knee arthroplasty (rUKA) significantly reduces all-cause revisions compared to conventional implantation (cUKA). This study aims to compare joint line-related parameters and their reconstruction accuracy between rUKA and cUKA. METHODS: Five databases were searched using a pre-defined strategy and inclusion criteria: (1) comparative studies reporting radiological outcomes, (2) human studies, (3) English language, and (4) meta-analyses for cross-referencing. Cadaveric or saw-bone studies were excluded. Data extracted included demographics data, pre- and postoperative radiological parameters (HKA, MPTA, LDFA, posterior tibial slope, femoral sagittal angle, joint line height, implant congruency), and outliers. A random-effects meta-analysis was conducted using mean difference (MD) and odds ratio (OR) as main effect estimators. Risk of bias was assessed using the Newcastle-Ottawa Scale (NOS), and publication bias was evaluated with funnel plots. RESULTS: A total of 18 studies assessing 2470 patients (1112 rUKA, 1358 cUKA) were included in the analysis. No significant baseline differences were found in age, sex, BMI, follow-up period, MPTA, LDFA, or tibial slope. Postoperative radiological parameters showed no significant differences between groups for HKA, LDFA, MPTA, or tibial slope (p > 0.05). Joint line height was significantly lower in cUKA compared to rUKA (MD = -1.37 mm, 95% CI: -2.06 to -0.69, p < 0.001). Outlier analysis revealed that rUKA had significantly fewer outliers across relevant radiological parameters, including HKA, joint line height, tibial slope, femoral flexion, femoral implant congruency, and medial, anterior, and posterior tibial congruency. CONCLUSION: Reporting pre- and postoperative mean alignment parameters undermines patient-specific anatomy reconstruction with advanced technologies. Outlier reporting showed significant variability, with limited evidence supporting its clinical relevance. Future studies should focus on patient-specific reconstruction and define clinical thresholds for outliers.
关键词
相关论文
Statistical Learning Theory
Yuhai Wu, Vladimir Vapnik
1999
Fractional Differential Equations
Igor Podlubný
2025
Applied Nonlinear Control
Jean-Jacques Slotine, Weiping Li
1991
Genetic Programming: On the Programming of Computers by Means of Natural Selection
John R. Koza
1992