1216 FACE AND CONSTRUCT VALIDITY ASSESSMENT OF 2ND GENERATION ROBOTIC SURGERY SIMULATOR
Ruslan Korets, Joseph A. Graversen, Adam C. Mues, Mantu Gupta, Jaime Landman, Ketan K. Badani
- 发表年份
- 2011
- 引用次数
- 8
摘要
You have accessJournal of UrologyTechnology & Instruments: Robotics/Laparoscopy1 Apr 20111216 FACE AND CONSTRUCT VALIDITY ASSESSMENT OF 2ND GENERATION ROBOTIC SURGERY SIMULATOR Ruslan Korets, Joseph A. Graversen, Adam C. Mues, Mantu Gupta, Jaime Landman, and Ketan K. Badani Ruslan KoretsRuslan Korets New York, NY More articles by this author , Joseph A. GraversenJoseph A. Graversen New York, NY More articles by this author , Adam C. MuesAdam C. Mues New York, NY More articles by this author , Mantu GuptaMantu Gupta New York, NY More articles by this author , Jaime LandmanJaime Landman Orange, CA More articles by this author , and Ketan K. BadaniKetan K. Badani New York, NY More articles by this author View All Author Informationhttps://doi.org/10.1016/j.juro.2011.02.872AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookTwitterLinked InEmail INTRODUCTION AND OBJECTIVES Simulation is an established component of surgical training, and may prove to be a valuable tool in acquisition of robotic surgery expertise (RSE). Before using a surgical simulator to train surgeons or assess competence, the simulator must be subjected to rigorous validation testing. The Mimic dV-Trainer® is a stand-alone virtual reality simulator platform for the da Vinci® Surgical System. The aim of this study was to assess face and construct validity of the 2nd generation Mimic dV-Trainer (MdVT). METHODS Between July 2010 and October 2010, 8 urology residents and 2 endourology fellows were assigned to Novice or Expert groups based on level of RSE. Each trainee completed 15 exercises from 4 domains. Performance was assessed using a built-in scoring algorithm, with multiple attempts allowed for each exercise until an overall score ≥80% was achieved. At the conclusion of all training modules, trainees completed a questionnaire assessing the ease of use and realism. Construct validity was analyzed by comparing the mean performance variables for the 2 groups (novice and experienced), using a 2-tailed t-test. RESULTS The median number of prior robotic surgery cases was 8 (range 0–15) for the novice group (NG) and 110 (range 55–170) for the expert group (EG). Compared to the novice group, the expert group had less instrument collisions (2.5 v 6.3 p<0.01), better “instrument out of view” scores (90.3 v 81.0 p=0.02), missed less targets within the “needle driving” domain (1.9 v 6.6 p<0.01), and performed better in the “work-space range” domain (93.9 v 79.8 p=0.01). There was no statistically significant difference between groups with respect to “excessive instrument force” score (p=NS) and number of “drops” (p=NS). The NG required more attempts to achieve score ≥80% (6.0 v 3.9 p=0.03). Both groups rated the MdVT as “easy to use” and “useful” in improving RSE with NG reporting improved confidence in robotic surgery skills after completing the training set. The EG rated MdVT as “somewhat realistic” in the “arm manipulation” and “camera movement” domains, but judged “needle control” and “needle driving” domains as “not realistic.” CONCLUSIONS The second generation MdVT demonstrates face and construct validity as a stand-alone robotic surgery simulator. Software updates may be necessary to improve utility of robotic suturing domain, and will require further validation. © 2011 by American Urological Association Education and Research, Inc.FiguresReferencesRelatedDetails Volume 185Issue 4SApril 2011Page: e488 Advertisement Copyright & Permissions© 2011 by American Urological Association Education and Research, Inc.MetricsAuthor Information Ruslan Korets New York, NY More articles by this author Joseph A. Graversen New York, NY More articles by this author Adam C. Mues New York, NY More articles by this author Mantu Gupta New York, NY More articles by this author Jaime Landman Orange, CA More articles by this author Ketan K. Badani New York, NY More articles by this author Expand All Advertisement Advertisement PDF downloadLoading
关键词
相关论文
Statistical Learning Theory
Yuhai Wu, Vladimir Vapnik
1999
Artificial intelligence: a modern approach
1995
Applied Nonlinear Control
Jean-Jacques Slotine, Weiping Li
1991
A new optimizer using particle swarm theory
R.C. Eberhart, James Kennedy
2002