Functional outcomes and health‐related quality of life after robot‐assisted anterior cruciate ligament reconstruction with patellar tendon grafts
Dirk Stengel, Frank Klufmöller, Grit Rademacher, Sven Mutze, K. Bauwens, K. Butenschön, Julia Seifert, M. Wich, Axel Ekkernkamp
- 发表年份
- 2009
- 引用次数
- 18
摘要
During a short period of time, surgical robots had been propagated for automated tunnel placement in anterior cruciate ligament (ACL) reconstruction. Clinical outcome data are currently unavailable. Between 2000 and 2003, 152 patients underwent ACL replacement with the assistance of the Computer Assisted Surgical Planning and Robotics system (CASPAR, OrtoMaquet, Germany) at our hospital. After minimal invasive pin placement in both the tibia and femur, computed tomography was used to register anatomical landmarks and to plan graft tunnel alignment. The robot was used to drill tibial and femoral tunnels in an outside-in fashion according to pre-operative planning. There was one procedure-specific Serious Adverse Event (i.e., an intraoperative transection of the posterior cruciate ligament). After IRB approval, all patients were invited for a follow-up examination. Data from 100 patients (35 women, 65 men, mean age 35 [SD 11] years, median follow-up 61 [range 42-77] months) form the basis of this report. Side-to-side differences in anterior laxity were measured with the KT-1000 arthrometer. Patient-centered outcomes included the Lysholm-Score, the lower extremity functional scale (LEFS), and the Short Form 36 (SF36). The mean KT-1000 side-to-side difference was 0.89 [95% confidence interval (CI) 0.52-1.26] mm. Eight and five patients had a positive Lachman and pivot shift test, respectively. The Lysholm-Score averaged 86 (95% CI 83-89) points. Excellent, good, fair, and poor outcomes were reported by 38, 32, 20, and 10 patients. The LEFS averaged 85 (95% CI 82-88) points. The mean SF36 Physical Component Score was 48.4 (95% CI 46.5-50.3), indicating residual deficits compared to the population norm. All tibial graft tunnels did not cross the Blumensaat line, but were placed slightly anterior to the optimal center of 42% reported in previous studies. Compared to literature data, robot-assisted ACL reconstruction with BTB grafts may lead to higher knee stability, but poorer functional outcomes. The immense additional efforts with the procedure did not pay off in a benefit to patients.
关键词
相关论文
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz 等 11 位作者
2012
Campbell-Walsh urology
Alan J. Wein editor-in-chief
2012
Stroke rehabilitation
Peter Langhorne, Julie Bernhardt, Gert Kwakkel
2011