Initial Experience with Robotic Epicardial Off-Pump Pulmonary Vein Isolation for Paroxysmal Atrial Fibrillation
Filip Casselman, İhsan Bakır, Pedro Brugada, Peter Geelen, Francis Wellens, Frank Van Praet, Ivan Gegrieck, Yvette Vermeulen, Hugo Vanermen
- 发表年份
- 2006
- 引用次数
- 2
摘要
OBJECTIVE: : To evaluate the feasibility and results of isolated endoscopic pulmonary vein isolation for paroxysmal atrial fibrillation using robotics. METHODS: : Between November 2004 and December 2005, 13 patients (38.5% female) underwent robotic pulmonary vein isolation at our institution. Mean age was 46.8 ± 8.4 years and mean preoperative duration of atrial fibrillation was 52.7 ± 31.5 months. Indication for surgery was symptomatic drug-refractory paroxysmal atrial fibrillation or recurrence after percutaneous treatment (n = 3). Mean preoperative left atrial dimension was 38.5 ± 6.9 mm. The surgical procedure was performed off-pump as an isolated right chest approach. All procedures were performed using the Flex 10 microwave ablator (Guidant, Indianapolis, IN), which was positioned from the right side through the transverse sinus and around the 4 pulmonary veins. Postoperative drug regimen included sotalol and Coumadin. Mean follow-up was 8.5 ± 3.4 months. RESULTS: : The procedure was successful in 11 patients. One patient needed conversion to median sternotomy for right pulmonary artery bleeding and a second patient had severe transverse sinus adhesions requiring conversion to a bilateral video-assisted small thoracotomy approach. No other morbidity occurred. Mean procedure time in successful cases was 2.7 ± 0.8 hours (range 1.7 to 4 hours). Permanent sinus rhythm was successfully restored in 10 of 13 patients (76.9% beyond 6 months). Nonsuccessful patients had markedly reduced symptoms and frequency of events. One patient required a left and another a right atrial flutter ablation during follow-up. CONCLUSIONS: : Robotic pulmonary vein isolation is a feasible procedure that has the potential to become a valid option in the treatment of paroxysmal atrial fibrillation.
关键词
相关论文
Quantitative Monitoring of Gene Expression Patterns with a Complementary DNA Microarray
Mark Schena, Dari Shalon, Ronald W. Davis 等 4 位作者
1995
Robots and Jobs: Evidence from US Labor Markets
Daron Acemoğlu, Pascual Restrepo
2019
Printing Proteins as Microarrays for High-Throughput Function Determination
Gavin MacBeath, Stuart L. Schreiber
2000
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Leigh R. Hochberg, Daniel Bacher, Beata Jarosiewicz 等 11 位作者
2012