Retrieval of aerosol properties from zenith sky radiance measurements
Sara Herrero‐Anta, Roberto Román, David Mateos, Ramiro González, Juan Carlos Antuña‐Sánchez, Marcos Herreras-Giralda, A. Fernando Almansa, Daniel González‐Fernández, Celia Herrero del Barrio, Carlos Toledano, Victoria E. Cachorro
- 发表年份
- 2023
- 引用次数
- 2
摘要
Abstract. This study explores the potential to retrieve aerosol properties with the GRASP algorithm (Generalized Retrieval of Atmosphere and Surface Properties) using as input measurements of zenith sky radiance (ZSR), which are sky radiances measured in the zenith direction, recorded at four wavelengths by a ZEN-R52 radiometer. To this end, the ZSR measured at 440, 500, 675 and 870 nm by a ZEN-R52 (ZSRZEN), installed in Valladolid (Spain), is employed. This instrument is calibrated intercomparing the signal of each channel with coincident ZSR values simulated (ZSRSIM) at the same wavelengths with a radiative transfer model (RTM). These simulations are carried out using the GRASP forward module as RTM and the aerosol information from a collocated CE318 photometer belonging to the AERONET network (Aerosol and Robotic Network) as input. Dark signal and the signal dependence on temperature are characterized and included in the calibration process. The uncertainties on each channel are quantified by an intercomparison with a collocated CE318 photometer, obtaining lower values for shorter wavelengths; between 3 % for 440 nm and 21 % for 870 nm. The proposed inversion strategy for the aerosol retrieval using the ZSRZEN measurements as input, so-called GRASP-ZEN, assumes the aerosol as an external mixture of five pre calculated aerosol types. A sensitivity analysis is conducted using synthetic ZSRZEN measurements, pointing out that these measurements are sensitive to aerosol load and type. It also assesses that the retrieved aerosol optical depth (AOD) values in general overestimates the reference ones by 0.03, 0.02, 0.02 and 0.01 for 440, 500, 675, 870 nm, respectively. The calibrated ZSRZEN measurements, recorded during two and half years at Valladolid, are inverted by GRASP-ZEN strategy to retrieve some aerosol properties like AOD. The retrieved AOD shows a high correlation with respect independent values obtained from the collocated AERONET CE318 photometer, with a determination coefficient (r2) about 0.86, 0.85, 0.79 and 0.72 for 440, 500, 675 and 870 nm, respectively, and finding uncertainties between 0.02 and 0.03 with respect to the AERONET values. Finally, it is studied the goodness of other retrieved aerosol properties like aerosol volume concentration for total, fine and coarse modes.
关键词
相关论文
Real-Time Obstacle Avoidance for Manipulators and Mobile Robots
Oussama Khatib
1986
A Mathematical Introduction to Robotic Manipulation
Richard M. Murray, Zexiang Li, Shankar Sastry
2017
Robot dynamics and control
Mark W. Spong
1989
A tutorial on visual servo control
Seth Hutchinson, Gregory D. Hager, Peter Corke
1996