In 2003, the work on environmental rehabilitation of the former coastal technical base of the Russian Navy in Gremikha town, with technical and financial support of the State Atomic Energy Corporation “Rosatom” and the French Alternative Energies and Atomic Energy Commission had begun. In 2017, the task of searching, characterization and packaging in transport containers for export to the long-term storage of high-level waste containing 152 Eu was set as part of this program. These wastes were presented as fragments of reactor control and safety system rods of first generation nuclear submarine reactors and were placed in temporary storage containers mixed with other radioactive waste and construction garbage on the territory of the Gremikha branch of the North-West Center “SevRAO”. To accomplish the task, the spectrometric system “Gamma-Pioneer” was developed and made at National Research Center “Kurchatov Institute”. The system consist of a collimated spectrometric gamma-ray CdZnTe detector 500 mm 3 volume, a dosimeter for continuous measurement of ambient equivalent dose rate at the instrument location and a color video camera with zoom lens. The device is placed in a protective frame and installed as an attachment implements on robot Brokk-90. Communication between the measuring system and the control computer is carried out using USB extender and 100 meters cable. The video camera is connected to the control computer via Ethernet. To search for the most active sources of gamma radiation, an equivalent dose rate calculation program using the results of measured instrumental spectra was developed. The characterization of the extracted fragments was carried out by activity evaluation of the main radionuclides polluting the samples under investigation. The paper describes design and operating principles of the system, as well as methods for the equivalent dose rate calculation and the activity evaluation of the fragments of reactor control and safety system rods based on spectral measurements obtained using the developed radiometric system
关键词
相关论文
Statistical Learning Theory
Yuhai Wu, Vladimir Vapnik
1999
Artificial intelligence: a modern approach
1995
Fractional Differential Equations
Igor Podlubný
2025
Applied Nonlinear Control
Jean-Jacques Slotine, Weiping Li
1991