The Feasibility and Reliability of Upper Arm–Worn Apple Watch Heart Rate Monitoring for Surgeons During Surgery: Observational Study
Kazunosuke Yamada, Yasuaki Enokida, Ryuji Kato, Jun Imaizumi, Takahiro Takada, Hitoshi Ojima
- 发表年份
- 2023
- 引用次数
- 2
- 访问权限
- 开放获取
摘要
BACKGROUND: Health care professionals, particularly those in surgical settings, face high stress levels, impacting their well-being. Traditional monitoring methods, like using Holter electrocardiogram monitors, are impractical in the operating room, limiting the assessment of physicians' health. Wrist-worn heart rate monitors, like the Apple Watch, offer promise but are restricted in surgeries due to sterility issues. OBJECTIVE: This study aims to assess the feasibility and accuracy of using an upper arm-worn Apple Watch for heart rate monitoring during robotic-assisted surgeries, comparing its performance with that of a wrist-worn device to establish a reliable alternative monitoring site. METHODS: This study used 2 identical Apple Watch Series 8 devices to monitor the heart rate of surgeons during robotic-assisted surgery. Heart rate data were collected from the wrist-worn and the upper arm-worn devices. Statistical analyses included calculating the mean difference and SD of difference between the 2 devices, constructing Bland-Altman plots, assessing accuracy based on mean absolute error and mean absolute percentage error, and calculating the intraclass correlation coefficient. RESULTS: The mean absolute errors for the whole group and for participants A, B, C, and D were 3.63, 3.58, 2.70, 3.93, and 4.28, respectively, and the mean absolute percentage errors were 3.58%, 3.34%, 2.42%, 4.58%, and 4.00%, respectively. Bland-Altman plots and scatter plots showed no systematic error when comparing the heart rate measurements obtained from the upper arm-worn and the wrist-worn Apple Watches. The intraclass correlation coefficients for participants A, B, C, and D were 0.559, 0.651, 0.508, and 0.563, respectively, with a significance level of P<.001, indicating moderate reliability. CONCLUSIONS: The findings of this study suggest that the upper arm is a viable alternative site for monitoring heart rate during surgery using an Apple Watch. The agreement and reliability between the measurements obtained from the upper arm-worn and the wrist-worn devices were good, with no systematic error and a high level of accuracy. These findings have important implications for improving data collection and management of the physical and mental demands of operating room staff during surgery, where wearing a watch on the wrist may not be feasible.
关键词
相关论文
A guide to deep learning in healthcare
Andre Esteva, Alexandre Robicquet, Bharath Ramsundar 等 10 位作者
2018
A review of shape memory alloy research, applications and opportunities
Jaronie Mohd Jani, Martin Leary, Aleksandar Subic 等 4 位作者
2013
Proceedings. 1985 IEEE International Conference on Robotics and Automation
1985
The dynamic window approach to collision avoidance
D. Fox, Wolfram Burgard, Sebastian Thrun
1997