首页 /研究 /SU‐E‐T‐268: Proton Radiosurgery End‐To‐End Testing Using Lucy 3D QA Phantom
SURGICAL

SU‐E‐T‐268: Proton Radiosurgery End‐To‐End Testing Using Lucy 3D QA Phantom

D Choi, Ian Gordon, A Ghebremedhin, Andrew Wroe, R. Schulte, David A. Bush, James Slater, B Patyal

发表年份
2014
引用次数
3

摘要

Purpose: To check the overall accuracy of proton radiosurgery treatment delivery using ready‐made circular collimator inserts and fixed thickness compensating boluses. Methods: Lucy 3D QA phantom (Standard Imaging Inc. WI, USA) inserted with GaFchromicTM film was irradiated with laterally scattered and longitudinally spread‐out 126.8 MeV proton beams. The tests followed every step in the proton radiosurgery treatment delivery process: CT scan (GE Lightspeed VCT), target contouring, treatment planning (Odyssey 5.0, Optivus, CA), portal calibration, target localization using robotic couch with image guidance and dose delivery at planned gantry angles. A 2 cm diameter collimator insert in a 4 cm diameter radiosurgery cone and a 1.2 cm thick compensating flat bolus were used for all beams. Film dosimetry (RIT114 v5.0, Radiological Imaging Technology, CO, USA) was used to evaluate the accuracy of target localization and relative dose distributions compared to those calculated by the treatment planning system. Results: The localization accuracy was estimated by analyzing the GaFchromic films irradiated at gantry 0, 90 and 270 degrees. We observed 0.5 mm shift in lateral direction (patient left), ±0.9 mm shift in AP direction and ±1.0 mm shift in vertical direction (gantry dependent). The isodose overlays showed good agreement (<2mm, 50% isodose lines) between measured and calculated doses. Conclusion: Localization accuracy depends on gantry sag, CT resolution and distortion, DRRs from treatment planning computer, localization accuracy of image guidance system, fabrication of ready‐made aperture and cone housing. The total deviation from the isocenter was 1.4 mm. Dose distribution uncertainty comes from distal end error due to bolus and CT density, in addition to localization error. The planned dose distribution was well matched (>90%) to the measured values 2%/2mm criteria. Our test showed the robustness of our proton radiosurgery treatment delivery system using ready‐made collimator inserts and fixed thickness compensating boluses.

关键词

IsocenterImaging phantomRadiosurgeryNuclear medicineCollimatorRadiation treatment planningProton therapyDosimetryPencil-beam scanningMedical imaging

相关论文

查看 SURGICAL 分类全部论文